EICR Holiday Lets

EICRs for holidaylets, done betweenguests.

We book the electrical inspection into your changeover: guests check out, the inspector arrives, the power is back on before the next check-in. No lost nights, a fixed price in writing, and the PDF report within 48 hours.

From £75

fixed in writing

48 hours

to your PDF report

2–5 hours

on site, most cottages

November

Example. Tap a free day.

Mon
Tue
Wed
Thu
Fri
Sat
Sun
2
3
4
5
6
7
8
Booked
Booked
9
10
11
12
13
14
15
​
Booked
16
17
18
19
20
21
22
​
Booked
Booked
23
24
25
26
27
28
29
​
Booked
Monday 16 November

Changeover

Guests
Inspector
Cleaners
08
10
12
14
16
18

Guests out at 10:00, inspector in at 10:15, power fully back on by about 13:30. The next guests arrive at 16:00 as normal.

Nobody arrives today, so the inspector has the whole afternoon. A good day for bigger houses or ones with a hot tub.

An empty morning before an afternoon arrival: inspect first, then the cleaners finish.

An empty night. Any time suits, and there’s room for repairs the same day if they’re small.

Guests are staying that night, so we wouldn’t book it. Pick a changeover or an empty day.

Who you're handing the key-safe code to

You usually won't be there, so it matters who walks in. These are standards every inspector we send holds, not badges we've made up.

Questions first? Call 020 3386 1854.

C&G 2391

Qualified to inspect and test existing installations

BS 7671

Reports written to the current wiring regulations

Photo ID

Shown to your housekeeper or neighbour at the door

Calibrated kit

Test instruments in date, so the readings stand up

Scheme number

Given on request, so you can look it up yourself

Ask for the scheme number
We'll give it when you book.

Check the public register
The scheme's own website lists its registered contractors.

Match the name on the report
Your EICR names the inspector and their qualifications.

Does a holiday let need an EICR?

It depends where the property is. Holiday guests aren't tenants, so the landlord EICR law doesn't reach them in England. Fire safety law does, and in Scotland the short-term let licence spells it out.

Fire safety law, not landlord law

The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 cover tenancies where someone lives as their only or main home. Holiday guests don't, so those regulations don't apply to a holiday let.

What does apply is the Regulatory Reform (Fire Safety) Order 2005. It covers any premises where you charge guests to stay and it isn't being lived in as a private home. The Home Office guide for small paying-guest accommodation (2024 update) puts the electrics plainly:

"You must make sure that your electrical wiring has been checked by a qualified contractor." The installation "should be subject to inspection and test at least every five years."

An EICR is the document that proves both. Your fire and rescue service enforces the Order, and it can ask to see your fire risk assessment and the evidence behind it.

  • WiringChecked by a qualified contractor; inspected and tested at least every 5 years.
  • AppliancesChecked regularly; in B&B-style lets, tested in line with the IET Code of Practice.
  • AlarmsThe guide recommends mains-powered, interlinked smoke and heat alarms.
  • Fire risk assessmentWritten down, reviewed regularly (usually yearly) and after any big change.
  • If you employ cleanersThe Electricity at Work Regulations 1989 also apply to the installation they work with.
  • RegistrationA national short-term let register is planned for England. As of October 2026 no start date is confirmed; check GOV.UK.

A licence condition, in black and white

Every short-term let in Scotland needs a licence from the council, and the mandatory conditions in Schedule 3 of the Licensing of Short-term Lets Order 2022 include electrical safety. Where guests can use or reach any electrical fittings or items, the licence holder must:

  • keep fittings and items in reasonable repair and safe working order;
  • arrange an electrical safety inspection by a competent person at least every five years, or sooner if that person says so;
  • make sure an Electrical Installation Condition Report is produced on the fixed installation;
  • get a Portable Appliance Testing report on the moveable appliances guests can use, with each one date-labelled and signed.

Source: SSI 2022/32, Schedule 3, paragraph 6. Your council's licence application pack says which documents to upload.

  • EICRAt least every 5 years, fixed installation.
  • PATReport on guest-accessible appliances; each labelled and signed.
  • GasAnnual gas safety inspection where there's gas (paragraph 5).
  • DetectionFire and carbon monoxide detection equipment (paragraph 3).
  • WaterLegionella risk assessed; private supplies managed (paragraphs 8–9).

Fire safety law, plus a new register

The Regulatory Reform (Fire Safety) Order 2005 applies to paying-guest accommodation in Wales too, with its own Welsh guidance. As in England, a current EICR is the clearest evidence for the electrical part of your fire risk assessment.

New for 2026: if you take bookings of 31 nights or less, you must register your visitor accommodation with the Welsh Revenue Authority by 31 March 2027, whether or not your council brings in the visitor levy. It's free. The register doesn't set electrical requirements itself.

The Welsh Government has also proposed a licensing scheme for visitor accommodation with safety standards. It isn't law yet, so check gov.wales before relying on any detail.

Source: gov.wales, Registering visitor accommodation (updated 8 October 2026).

  • WiringEvidence for your fire risk assessment; every 5 years is standard practice.
  • RegisterBy 31 March 2027 for stays of 31 nights or less.
  • Long letsA Welsh occupation contract has its own electrical rules (5-yearly report).

Certification first

Self-catering accommodation in Northern Ireland needs a certificate from Tourism NI before you can take guests, and fire safety law applies to paying-guest premises. Ask Tourism NI what electrical evidence they want to see for your property type.

If the property is let to someone as their home instead, the Electrical Safety Standards for Private Tenancies Regulations (Northern Ireland) 2024 apply: an inspection at least every five years.

  • Holiday letTourism NI certification; check their current requirements.
  • TenancyEICR every 5 years under the 2024 NI regulations.

What applies to your let?

Four questions. You get the list of electrical duties for your setup, with where each one comes from.

Where is it?
England
Scotland
Wales
What kind of let?
Whole house or flat
Room in my own home
Lodge, caravan or glamping
Out of season, does anyone live there as their home?
No, holiday stays only
Yes, a winter or long let
Do you pay anyone to work there?
Yes, cleaners or a housekeeper
No, I do it myself

Whole house or flat in England

Your electrical duties, as we read the sources. Not legal advice.

Short-term let licence (home sharing type)

Rooms in your own home still need a licence. The electrical condition applies where guests can use electrical items.

Short-term let licence from your council

Mandatory conditions in Schedule 3 of the 2022 Order.

EICR at least every 5 years

Fixed installation, by a competent person; sooner if they direct (Sch 3 para 6).

PAT report, every appliance labelled

Moveable appliances guests can use, date-labelled and signed.

Fire risk assessment, written down

Regulatory Reform (Fire Safety) Order 2005, which covers paying guests.

Wiring checked by a qualified contractor

Home Office guide: inspected and tested at least every 5 years. An EICR shows it.

Appliances checked regularly

PAT testing is the usual way to record it.

Register with the Welsh Revenue Authority

By 31 March 2027 for stays of 31 nights or less. Free.

Short-term let register: not live yet

Planned for England; no confirmed start date as of October 2026.

Shorter interval likely

Caravans have their own BS 7671 section; IET GN3 suggests every 3 years. Hook-up points are checked too.

Fire Safety Order may still apply

Paying guests who aren’t friends or family make it more likely; check the Home Office guide.

Electricity at Work Regulations 1989

Your cleaners work with the installation, so keep it safe and maintained.

Landlord rules for the winter let

S.I. 2020/312: satisfactory EICR before the tenancy starts, copy to the tenant before they move in, up to £40,000 per breach.

Occupation contract rules for the long let

Renting Homes (Wales): electrical report every 5 years and a copy to the contract-holder.

Private residential tenancy rules

Repairing standard: EICR and PAT every 5 years for the long let too.

A typical two-bedroom cottage

Changeover day, with an EICR in it

Scroll through the day. Bigger homes, outbuildings and hot tubs take longer, and we'll tell you before booking whether to block a night.

09:45
Power on
09:45

Access sorted the day before

You send the key-safe code or put us in touch with your housekeeper. If you have a smart lock that needs Wi-Fi, tell us, because the router will lose power for part of the visit.

10:00

Guests check out

Nothing happens until they've gone. If they're late, we wait or start outside with the meter tails, garden sockets and outbuilding.

10:15

Visual inspection, room by room

The consumer unit, sockets, switches, light fittings, bathrooms, the kitchen, the loft where it's safe to reach. Cleaners can carry on around us.

11:20

Dead testing, one circuit at a time

Continuity and insulation resistance need circuits switched off. Keep the fridge and freezer shut; an hour or two off won't spoil them if the doors stay closed.

12:40

Live testing

Power back on. Earth fault loop impedance, RCD trip times and polarity, including the hot tub supply and any EV charger.

13:35

Everything reset, results by phone

Clocks, timers, hot tub and Wi-Fi back up. The inspector calls you with the result before leaving. A C1 danger is made safe there and then.

16:00

Next guests check in

The house is ready on time. Your PDF report arrives within 48 hours, and we remind you before the next one is due.

Want to check your changeover window works? Tell us your checkout and check-in times and the number of bedrooms.

Prices by bedroom, fixed before we book

The range depends on the number of circuits and boards. We confirm your exact price in writing on the call, and it doesn't change on the day.

Studio or 1 bedroom

Flats, apartments, annexes

£75–£98.99

one consumer unit

2–3 bedrooms

Cottages, townhouses, larger flats

£98.99

one consumer unit

4–5 bedrooms

Farmhouses, family houses

£109.99–£149.99

one consumer unit

Bigger, or different

6+ bedrooms, lodges, static caravans, glamping, several units on one site

Priced on the call

fixed in writing before booking

What's included
Full inspection and testing, the EICR as a PDF within 48 hours, and a phone call with the results on the day.

What can add to it
Extra consumer units, outbuildings, a hot tub, sauna or EV charger. Tell us on the call and it's in the written price.

PAT testing
Needed for a Scottish licence, sensible everywhere. Done on the same visit; we quote it on the call.

Prices quoted for one visit. If something fails, the repair quote is separate, itemised, and you're free to use any electrician.

Estimate it like a booking

Count bedrooms and boards the way you'd count guests. Extras don't change the band here; they're added to your written price on the call.

Bedrooms

Count a studio as 1

−
2
+
Consumer units (fuse boards)

Include one in a garage or annexe

−
1
+
Hot tub
EV charger
Sauna
Outbuilding or games room
Add PAT testing
Garden lighting or sockets

Your band

£98.99

2 bedrooms, one consumer unit.

  • No extras ticked

The amenities an inspector looks at hardest

The things that make a listing stand out are often the ones that add circuits, outdoor cables and water near electricity. Tap one to see what gets checked.

Hot tub

A dedicated circuit with 30mA RCD protection, an outdoor isolator within reach, the cable route and how it's protected, and the condition of the plug-in connection if it's a portable tub.

EV charger for guests

Charge points have their own section of BS 7671 (722). The inspector checks the supply, RCD type, earthing arrangement and the charger's own protection.

Sauna or steam room

Heater supply, cable types rated for the heat, the temperature zones in BS 7671 section 703 and RCD protection.

Electric shower

Cable size against the shower's rating, the isolator, bathroom zones (BS 7671 section 701) and supplementary bonding where it's needed.

Garden lighting and outdoor sockets

RCD protection on outdoor circuits, weatherproof enclosures, buried or clipped cable routes, and festoon lights plugged into indoor sockets through windows.

Outbuilding, games room or annexe

The sub-main cable to it, its own board, earthing arrangements in a detached building, and damp or rodent damage to cables.

Smart lock, key box and Wi-Fi

Not tested as such, but planned around: we need to know what loses power during dead testing, so nobody gets locked out and the router comes back for the next guests.

Kitchen: oven, hob, extractor

Cooker circuit rating and isolator, sockets near the sink, the hob connection and heat damage behind built-in appliances.

Storage heaters and immersion

Off-peak circuits, the immersion heater flex and switch, and timers that need resetting afterwards so guests aren't left with cold water.

Static caravan or lodge hook-up

Caravans have their own BS 7671 section (721) and parks another (708). IET Guidance Note 3 suggests inspecting caravans every three years.

What the codes on your report mean for the next booking

Each finding gets a code. Turn the hangers over: the back says whether the next guests can check in.

C1
Danger present

Tap to turn over

What it means

Risk of injury right now, such as exposed live parts.

Next guests?

No, not until it's fixed. The inspector makes it safe or isolates it before leaving.

C2
Potentially dangerous

Tap to turn over

What it means

Could become dangerous, such as missing RCD protection where it's needed.

Next guests?

Get it fixed before the next booking if you can; treat it as urgent.

C3
Improvement recommended

Tap to turn over

What it means

Not to current standard, but not dangerous. A C3 alone doesn't fail the report.

Next guests?

Yes. Plan the work for the quiet season.

FI
Further investigation

Tap to turn over

What it means

Something couldn't be confirmed on the day and needs a closer look.

Next guests?

Book the investigation quickly; the report stays unsatisfactory until it's done.

Any C1, C2 or FI makes the report unsatisfactory. You get an itemised quote with no pressure, and any qualified electrician can do the work.

Book it in your quiet season

Mark your busy months and enter your last EICR. The planner finds your due date and the quietest month to book before it.

Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
Last EICR, month

Never or not sure

Year

2022

Interval on the report

5 years

Your plan

Next inspection due by

Now (no record)

Suggested booking month

November 2026

Without a previous report, book the first quiet month you can. In Scotland you’ll need one for the licence anyway.

The paperwork behind a safe holiday let

What to keep in your records, and what's worth a line in the welcome book. Open each divider.

Electrical Installation Condition Report

The EICR covers the fixed wiring: the board, circuits, sockets, switches and fixed appliances. Keep it until the next one, and give a copy to whoever does the following inspection, so they can compare.

  • England and Wales: evidence for your fire risk assessment.
  • Scotland: needed for your licence (upload with the application).
  • Agencies and insurers: some ask for it. Check your owner pack and policy.

PAT records and labels

Kettles, toasters, lamps, hairdryers, TVs: anything with a plug that guests use. In Scotland each appliance needs a dated, signed label and there must be a PAT report. Elsewhere, regular checks are the guidance, and a PAT record shows you've done them.

Between lets, the Home Office guide suggests a quick look at plugs, flexes and white goods.

Fire risk assessment

Required under the Fire Safety Order for paying-guest accommodation, and it has to be written down. Review it regularly (yearly is usual) and after any significant change, like a new hot tub or a loft conversion.

The electrical section is where the EICR date and result go.

Gas safety record

Where there's gas, appliances should be checked and serviced every year by a Gas Safe registered engineer. In Scotland the annual gas inspection is a licence condition. Not our job, but it belongs in the same folder.

Alarm and emergency-light log

Smoke and heat alarm tests, emergency lighting or torch checks, and any faults. The Home Office guide suggests a log book or an electronic record. Mains-powered interlinked alarms are recommended; the inspector will note the alarm circuit on the report.

Welcome book line

Guests don't need the full report, but a short line in the house manual shows you take safety seriously and tells them where the consumer unit is if something trips. Use the generator further down to write it.

When a holiday let stops being a holiday let

Plenty of coastal and country homes switch to a winter or long let. The moment someone lives there as their home, landlord law applies in full.

Holiday guests

Main law (England)
Regulatory Reform (Fire Safety) Order 2005
Electrical inspection
Wiring checked by a qualified contractor; at least every 5 years (Home Office guide)
Copies
Keep it on file; show the fire service if asked
Enforced by
Fire and rescue service

Winter or long let, as someone's home

Main law (England)
Electrical Safety Standards Regulations 2020
Electrical inspection
Satisfactory EICR before the tenancy starts, then at least every 5 years
Copies
To the tenant before they move in; to the council within 7 days if asked
Enforced by
The council, with penalties up to £40,000 per breach

A room in your own home

Main law (England)
Fire Safety Order may still apply if guests pay and aren't friends or family
Electrical inspection
Same Home Office guidance; the 2020 regulations exclude lodgers sharing with you
Copies
Keep it with your fire risk assessment
Enforced by
Fire and rescue service

Tenancies in England also changed on 1 May 2026 under the Renters' Rights Act 2025. Get advice on the tenancy itself before offering winter lets. Sources: S.I. 2020/312 as amended by S.I. 2025/1043; Home Office paying-guest guide.

If repairs are needed, block the nights, not the season

Most remedial work on a holiday let fits into one or two blocked nights. You'll know exactly what's needed before you decide.

January

Example

12
13
14
15
16
17
18
19
20
21
Booked
Repairs
Booked

The inspection found two C2s on a Tuesday changeover. Two nights blocked in January, the next guests arrive as planned, and the written confirmation goes in the folder.

A line for your welcome book

Fill in your report details and copy a short, factual paragraph for the house manual or your listing.

Date of inspection

2026-11-16

Next inspection due

2031-11-16

Where's the consumer unit (fuse board)?

the cupboard under the stairs

Who should guests call if the power trips?

your host

Appliances were PAT tested too

House manual: electrics

The electrical installation in this property was inspected and tested by a qualified electrician on {inspection date}. The next inspection is due by {next date}.[pat] The appliances provided for your use have been safety tested.[/pat]

If the power goes off, the consumer unit (fuse board) is in {location}. If a switch trips again after you reset it, please leave it off and contact {contact}.

Before changeover day

Tick these off and the inspection fits the window. Turn the sign by finishing the list.

Share access

Key-safe code, door code or your housekeeper's number.

Tell us what loses power

Smart lock, Wi-Fi key box, cameras, hot tub timer, heating controls.

Clear the consumer unit

Not behind the linen stack or the vacuum.

Unlock the outbuildings

Garage, shed, games room, owner's cupboard, hot tub cover.

Warn the cleaners

Power goes off in sections for part of the visit.

Find the last report

And note anything guests mentioned, like a trip switch that keeps going.

0 of 6 done

Holiday-let questions

The ones owners ask on the phone.

No regulation in England names an EICR for holiday lets. The Electrical Safety Standards regulations of 2020 cover tenancies where someone lives as their main home, and holiday guests don't. But the Regulatory Reform (Fire Safety) Order 2005 applies to paying-guest accommodation, and the Home Office guide for small paying-guest accommodation says you must make sure your electrical wiring has been checked by a qualified contractor and that the installation should be inspected and tested at least every five years. An EICR is the standard document that shows this was done.

Yes. Paragraph 6 of Schedule 3 to the Licensing of Short-term Lets Order 2022 makes it a mandatory licence condition: an electrical safety inspection by a competent person at least every five years (or sooner if they direct), an Electrical Installation Condition Report on the fixed installation, and a Portable Appliance Testing report for appliances guests can use, with each appliance date-labelled and signed.

The Fire Safety Order applies to paying-guest accommodation in Wales too, with its own Welsh guidance. Separately, anyone taking bookings of 31 nights or less must register their visitor accommodation with the Welsh Revenue Authority by 31 March 2027. Registration is free and the register itself does not set electrical requirements, so a current EICR remains the practical evidence for the electrical part of your fire risk assessment.

Every five years is the standard: it is what the Home Office guide recommends for England and what the Scottish licence condition requires. The inspector can set a shorter interval if the installation needs it, for example with older wiring, a hot tub or very heavy use. IET Guidance Note 3 suggests three years for caravans.

Usually, yes. Most cottages and flats take 2 to 5 hours depending on size and the number of circuits. We start soon after guests check out and aim to have the power fully back on well before the next check-in. For larger houses, or ones with outbuildings and a hot tub, we may suggest blocking one night.

In sections, for part of the visit. Dead testing needs circuits switched off, so keep fridges and freezers closed, and tell us about smart locks, Wi-Fi-only key boxes, hot tub timers and anything that needs resetting. Cleaners can usually work alongside the inspector, though the vacuum may have to wait for a circuit.

No. Most holiday-let owners give us the key-safe code or put us in touch with their housekeeper. The inspector calls you with the results before leaving, and the PDF report follows within 48 hours.

In Scotland, yes: the licence condition needs a PAT report and each appliance labelled. In England and Wales the Home Office guide says appliances should be checked regularly, and for bed-and-breakfast style accommodation tested in line with the IET Code of Practice. Many hosts test the appliances guests use. We can do both in one visit and will quote the PAT part on the call.

Any C1, C2 or FI code makes the report unsatisfactory. You get an itemised quote for the repairs, with no pressure to use us; any qualified electrician can do the work. Don't take guests while a C1 danger is present: the inspector will make it safe or isolate it before leaving.

If someone lives there as their only or main home, it is a tenancy and the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 apply: a satisfactory EICR before the tenancy starts, a copy to the tenant before they move in, and civil penalties of up to £40,000 per breach. Get advice on the tenancy itself too, as the Renters' Rights Act 2025 changed tenancies in England from 1 May 2026.

It can add circuits and time, so tell us about them on the call. The price is confirmed in writing before you book, and it does not change on the day.

Holiday lets are often rural, so call 020 3386 1854 with the postcode. We will tell you straight away whether an inspector covers it, before you book anything.

Pick a changeover, we'll do the rest

Send the details and we'll call back with a fixed price and the first changeover slot that works.

Rather talk it through?

Tell us the postcode, bedrooms and your changeover times.